Neels Hofmeyr | 1a3eaef | 2020-11-18 16:25:55 +0100 | [diff] [blame] | 1 | # No Hysteresis and minimum RX level |
| 2 | # If current cell's RX level is below mimium level, handover must be |
| 3 | # performed, no matter of the hysteresis. First do not perform |
| 4 | # handover to better neighbor cell, because the hysteresis is not |
| 5 | # met. Second do not perform handover because better neighbor cell is |
| 6 | # below minimum RX level. Third perform handover because current cell |
| 7 | # is below minimum RX level, even if the better neighbor cell (minimum |
| 8 | # RX level reached) does not meet the hysteresis. |
| 9 | |
| 10 | create-n-bts 2 |
| 11 | set-ts-use trx 0 0 states * TCH/F - - - - - - |
| 12 | meas-rep lchan 0 0 1 0 rxlev 10 rxqual 0 ta 0 neighbors 11 |
| 13 | expect-no-chan |
| 14 | meas-rep lchan 0 0 1 0 rxlev 8 rxqual 0 ta 0 neighbors 9 |
| 15 | expect-no-chan |
| 16 | meas-rep lchan 0 0 1 0 rxlev 9 rxqual 0 ta 0 neighbors 10 |
| 17 | expect-ho from lchan 0 0 1 0 to lchan 1 0 1 0 |
| 18 | expect-ts-use trx 0 0 states * - - - - - - - |
| 19 | expect-ts-use trx 1 0 states * TCH/F - - - - - - |
| 20 | |