| # No Hysteresis and minimum RX level |
| # If current cell's RX level is below mimium level, handover must be |
| # performed, no matter of the hysteresis. First do not perform |
| # handover to better neighbor cell, because the hysteresis is not |
| # met. Second do not perform handover because better neighbor cell is |
| # below minimum RX level. Third perform handover because current cell |
| # is below minimum RX level, even if the better neighbor cell (minimum |
| # RX level reached) does not meet the hysteresis. |
| |
| create-n-bts 2 |
| set-ts-use trx 0 0 states * TCH/F - - - - - - |
| meas-rep lchan 0 0 1 0 rxlev 10 rxqual 0 ta 0 neighbors 11 |
| expect-no-chan |
| meas-rep lchan 0 0 1 0 rxlev 8 rxqual 0 ta 0 neighbors 9 |
| expect-no-chan |
| meas-rep lchan 0 0 1 0 rxlev 9 rxqual 0 ta 0 neighbors 10 |
| expect-ho from lchan 0 0 1 0 to lchan 1 0 1 0 |
| expect-ts-use trx 0 0 states * - - - - - - - |
| expect-ts-use trx 1 0 states * TCH/F - - - - - - |
| |