Supreeth Herle | 4c306ab | 2020-03-18 11:38:00 +0100 | [diff] [blame] | 1 | Using PC/SC reader (dev=3) interface |
Philipp Maier | 9f9c609 | 2019-09-02 14:33:02 +0200 | [diff] [blame] | 2 | Reading ... |
Supreeth Herle | 4c306ab | 2020-03-18 11:38:00 +0100 | [diff] [blame] | 3 | Autodetected card type: Wavemobile-SIM |
Philipp Maier | 9f9c609 | 2019-09-02 14:33:02 +0200 | [diff] [blame] | 4 | ICCID: 89445310150011013678 |
| 5 | IMSI: 001010000000102 |
Supreeth Herle | 4c306ab | 2020-03-18 11:38:00 +0100 | [diff] [blame] | 6 | GID1: Can't read file -- SW match failed! Expected 9000 and got 6a82. |
| 7 | GID2: Can't read file -- SW match failed! Expected 9000 and got 6a82. |
Philipp Maier | 9f9c609 | 2019-09-02 14:33:02 +0200 | [diff] [blame] | 8 | SMSP: e1ffffffffffffffffffffffff0581005155f5ffffffffffff000000ffffffffffffffffffffffffffff |
Supreeth Herle | f829945 | 2019-06-08 07:49:08 +0200 | [diff] [blame] | 9 | SPN: wavemobile |
| 10 | Display HPLMN: False |
| 11 | Display OPLMN: False |
Philipp Maier | 9f9c609 | 2019-09-02 14:33:02 +0200 | [diff] [blame] | 12 | PLMNsel: fff11fffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff |
| 13 | PLMNwAcT: |
Supreeth Herle | d24f163 | 2019-11-30 10:37:09 +0100 | [diff] [blame] | 14 | fff11fffff # MCC: 001 MNC: 001 AcT: UTRAN, E-UTRAN, GSM, GSM COMPACT, cdma2000 HRPD, cdma2000 1xRTT |
Philipp Maier | 9f9c609 | 2019-09-02 14:33:02 +0200 | [diff] [blame] | 15 | ffffff0000 # unused |
| 16 | ffffff0000 # unused |
| 17 | ffffff0000 # unused |
| 18 | ffffff0000 # unused |
| 19 | ffffff0000 # unused |
| 20 | ffffff0000 # unused |
| 21 | ffffff0000 # unused |
| 22 | ffffff0000 # unused |
| 23 | ffffff0000 # unused |
| 24 | ffffff0000 # unused |
| 25 | ffffff0000 # unused |
| 26 | ffffff0000 # unused |
| 27 | ffffff0000 # unused |
| 28 | ffffff0000 # unused |
| 29 | ffffff0000 # unused |
| 30 | |
| 31 | OPLMNwAcT: |
Supreeth Herle | d24f163 | 2019-11-30 10:37:09 +0100 | [diff] [blame] | 32 | fff11fffff # MCC: 001 MNC: 001 AcT: UTRAN, E-UTRAN, GSM, GSM COMPACT, cdma2000 HRPD, cdma2000 1xRTT |
Philipp Maier | 9f9c609 | 2019-09-02 14:33:02 +0200 | [diff] [blame] | 33 | ffffff0000 # unused |
| 34 | ffffff0000 # unused |
| 35 | ffffff0000 # unused |
| 36 | ffffff0000 # unused |
| 37 | ffffff0000 # unused |
| 38 | ffffff0000 # unused |
| 39 | ffffff0000 # unused |
| 40 | ffffff0000 # unused |
| 41 | ffffff0000 # unused |
| 42 | ffffff0000 # unused |
| 43 | ffffff0000 # unused |
| 44 | ffffff0000 # unused |
| 45 | ffffff0000 # unused |
| 46 | ffffff0000 # unused |
| 47 | ffffff0000 # unused |
| 48 | |
Supreeth Herle | 4c306ab | 2020-03-18 11:38:00 +0100 | [diff] [blame] | 49 | HPLMNAcT: Can't read file -- SW match failed! Expected 9000 and got 6a82. |
Philipp Maier | 9f9c609 | 2019-09-02 14:33:02 +0200 | [diff] [blame] | 50 | ACC: abce |
| 51 | MSISDN: Not available |
| 52 | AD: 00ffff02 |
Supreeth Herle | e26331e | 2020-03-20 18:50:39 +0100 | [diff] [blame^] | 53 | SIM Service Table: ff33ff0f3c00ff0f000cf0c0f0030000 |
| 54 | Service 1 - CHV1 disable function: True |
| 55 | Service 2 - Abbreviated Dialling Numbers (ADN): True |
| 56 | Service 3 - Fixed Dialling Numbers (FDN): True |
| 57 | Service 4 - Short Message Storage (SMS): True |
| 58 | Service 5 - Advice of Charge (AoC): True |
| 59 | Service 6 - Capability Configuration Parameters (CCP): True |
| 60 | Service 7 - PLMN selector: True |
| 61 | Service 8 - RFU: True |
| 62 | Service 9 - MSISDN: True |
| 63 | Service 10 - Extension1: True |
| 64 | Service 13 - Last Number Dialled (LND): True |
| 65 | Service 14 - Cell Broadcast Message Identifier: True |
| 66 | Service 17 - Service Provider Name: True |
| 67 | Service 18 - Service Dialling Numbers (SDN): True |
| 68 | Service 19 - Extension3: True |
| 69 | Service 20 - RFU: True |
| 70 | Service 21 - VGCS Group Identifier List (EFVGCS and EFVGCSS): True |
| 71 | Service 22 - VBS Group Identifier List (EFVBS and EFVBSS): True |
| 72 | Service 23 - enhanced Multi-Level Precedence and Pre-emption Service: True |
| 73 | Service 24 - Automatic Answer for eMLPP: True |
| 74 | Service 25 - Data download via SMS-CB: True |
| 75 | Service 26 - Data download via SMS-PP: True |
| 76 | Service 27 - Menu selection: True |
| 77 | Service 28 - Call control: True |
| 78 | Service 35 - Short Message Status Reports: True |
| 79 | Service 36 - Network's indication of alerting in the MS: True |
| 80 | Service 37 - Mobile Originated Short Message control by SIM: True |
| 81 | Service 38 - GPRS: True |
| 82 | Service 49 - MExE: True |
| 83 | Service 50 - Reserved and shall be ignored: True |
| 84 | Service 51 - PLMN Network Name: True |
| 85 | Service 52 - Operator PLMN List: True |
| 86 | Service 53 - Mailbox Dialling Numbers: True |
| 87 | Service 54 - Message Waiting Indication Status: True |
| 88 | Service 55 - Call Forwarding Indication Status: True |
| 89 | Service 56 - Service Provider Display Information: True |
| 90 | Service 57 - Multimedia Messaging Service (MMS): True |
| 91 | Service 58 - Extension 8: True |
| 92 | Service 59 - MMS User Connectivity Parameters: True |
Philipp Maier | 9f9c609 | 2019-09-02 14:33:02 +0200 | [diff] [blame] | 93 | Done ! |