| The Siemens BS-11 supports the following additional GSM 12.21 OML operations: |
| |
| |
| CREATE OBJECT |
| |
| abis_om_fom_hdr.obj_class can be |
| A3: |
| A5: ALCO, BBSIG, CCLK, GPSU, LI, PA |
| A8: EnvaBTSE |
| A9: BPORT |
| |
| the abis_om_obj_inst.trx_nr field indicates the index of object, whereas the |
| abis_om_fom_hdr.bts_nr indicates the type of the object. |
| |
| enum abis_bs11_objtype { |
| BS11_OBJ_ALCO = 0x01, |
| BS11_OBJ_BBSIG = 0x02, /* obj_class: 0,1 */ |
| BS11_OBJ_TRX1 = 0x03, /* only DEACTIVATE TRX1 */ |
| BS11_OBJ_CCLK = 0x04, |
| BS11_OBJ_GPSU = 0x06, |
| BS11_OBJ_LI = 0x07, |
| BS11_OBJ_PA = 0x09, /* obj_class: 0, 1*/ |
| }; |
| |
| In case of CREATE ENVABTSE, the abis_om_obj_inst.trx_nr indicates the EnvaBTSEx |
| number. |
| |
| In case of A9 (CREAETE BPORT), the abis_om_obj_inst.bts_nr indicates which BPORT |
| shall be used. |
| |
| |