| OsmoBSC> show network |
| ... |
| Handover: Off |
| ... |
| OsmoBSC> enable |
| |
| OsmoBSC# ### No handover config present |
| OsmoBSC# show running-config |
| ... !handover |
| |
| OsmoBSC# ### Toggling handover on network level affects 'show network': |
| OsmoBSC# configure terminal |
| OsmoBSC(config)# network |
| OsmoBSC(config-net)# do show network |
| ... |
| Handover: Off |
| ... |
| OsmoBSC(config-net)# handover 1 |
| OsmoBSC(config-net)# do show network |
| ... |
| Handover: On |
| ... |
| |
| OsmoBSC(config-net)# ### If network level default is 'on', bts level can still override to 'off': |
| OsmoBSC(config-net)# bts 0 |
| OsmoBSC(config-net-bts)# handover 0 |
| OsmoBSC(config-net-bts)# do show network |
| ... |
| Handover: Off |
| ... |
| OsmoBSC(config-net-bts)# exit |
| |
| OsmoBSC(config-net)# ### Create a *second* BTS that is not explicitly 'off': |
| OsmoBSC(config-net)# bts 1 |
| OsmoBSC(config-net-bts)# do show network |
| ... |
| Handover: On at 1 BTS, Off at 1 BTS |
| ... |
| |
| OsmoBSC(config-net-bts)# ### Add arbitrary handover config item for bts 1: |
| OsmoBSC(config-net-bts)# handover power budget interval 23 |
| OsmoBSC(config-net-bts)# exit |
| OsmoBSC(config-net)# ### HO is 'on' globally, bts 0 disables it, bts 1 tweaks a param: |
| OsmoBSC(config-net)# show running-config |
| ... |
| network |
| ... !handover |
| handover 1 |
| ... !handover |
| bts 0 |
| ... !handover |
| handover 0 |
| ... !handover |
| bts 1 |
| ... !handover |
| handover power budget interval 23 |
| ... !handover |
| |
| OsmoBSC(config-net)# ### Set global default to 'off', now bts 1 also uses the global default of 'off': |
| OsmoBSC(config-net)# handover 0 |
| OsmoBSC(config-net)# do show network |
| ... |
| Handover: Off |
| ... |
| OsmoBSC(config-net)# show running-config |
| ... |
| network |
| ... !handover |
| handover 0 |
| ... !handover |
| bts 0 |
| ... !handover |
| handover 0 |
| ... !handover |
| bts 1 |
| ... !handover |
| handover power budget interval 23 |
| ... !handover |
| |
| OsmoBSC(config-net)# ### Remove the global setting, i.e. use the factory default net level, with same effect: |
| OsmoBSC(config-net)# handover default |
| % 'handover' setting removed, now is 0 |
| OsmoBSC(config-net)# handover default |
| % 'handover' already was unset, still is 0 |
| OsmoBSC(config-net)# do show network |
| ... |
| Handover: Off |
| ... |
| OsmoBSC(config-net)# show running-config |
| ... |
| network |
| ... !handover |
| bts 0 |
| ... !handover |
| handover 0 |
| ... !handover |
| bts 1 |
| ... !handover |
| handover power budget interval 23 |
| ... !handover |
| |
| OsmoBSC(config-net)# ### Re-enable net-level handover, but bts 0 remains disabled explicitly |
| OsmoBSC(config-net)# handover 1 |
| OsmoBSC(config-net)# do show network |
| ... |
| Handover: On at 1 BTS, Off at 1 BTS |
| ... |
| OsmoBSC(config-net)# show running-config |
| ... |
| network |
| ... !handover |
| handover 1 |
| ... !handover |
| bts 0 |
| ... !handover |
| handover 0 |
| ... !handover |
| bts 1 |
| ... !handover |
| handover power budget interval 23 |
| ... !handover |
| |
| OsmoBSC(config-net)# ### Remove explicit setting of bts 0 to also use the global setting: |
| OsmoBSC(config-net)# bts 0 |
| OsmoBSC(config-net-bts)# handover default |
| % 'handover' setting removed, now is 1 (set on higher level node) |
| OsmoBSC(config-net-bts)# handover default |
| % 'handover' already was unset, still is 1 (set on higher level node) |
| OsmoBSC(config-net-bts)# do show network |
| ... |
| Handover: On |
| ... |
| OsmoBSC(config-net-bts)# show running-config |
| ... |
| network |
| ... !handover |
| handover 1 |
| ... !handover |
| bts 0 |
| ... !handover |
| bts 1 |
| ... !handover |
| handover power budget interval 23 |
| ... !handover |
| |
| OsmoBSC(config-net-bts)# ### Verify that 'min rxlev' value range stops at -50 |
| OsmoBSC(config-net-bts)# handover2 min rxlev ? |
| <-110--50> minimum RxLev (dBm) |
| default Use default (-100), remove explicit setting on this node |
| OsmoBSC(config-net-bts)# handover2 min rxlev -111 |
| % Unknown command. |
| OsmoBSC(config-net-bts)# handover2 min rxlev -110 |
| OsmoBSC(config-net-bts)# handover2 min rxlev -50 |
| OsmoBSC(config-net-bts)# handover2 min rxlev -49 |
| % Unknown command. |
| OsmoBSC(config-net-bts)# handover2 min rxlev 50 |
| % Unknown command. |
| OsmoBSC(config-net-bts)# handover2 min rxlev default |
| % 'handover2 min rxlev' setting removed, now is -100 |
| |
| |
| OsmoBSC(config-net-bts)# ### Checking online help |
| OsmoBSC(config-net-bts)# exit |
| OsmoBSC(config-net)# list |
| ... |
| handover (0|1|default) |
| handover algorithm (1|2|default) |
| handover window rxlev averaging (<1-10>|default) |
| handover window rxqual averaging (<1-10>|default) |
| handover window rxlev neighbor averaging (<1-10>|default) |
| handover power budget interval (<1-99>|default) |
| handover power budget hysteresis (<0-999>|default) |
| handover maximum distance (<0-9999>|default) |
| handover2 window rxlev averaging (<1-10>|default) |
| handover2 window rxqual averaging (<1-10>|default) |
| handover2 window rxlev neighbor averaging (<1-10>|default) |
| handover2 power budget interval (<1-99>|default) |
| handover2 power budget hysteresis (<0-999>|default) |
| handover2 maximum distance (<0-9999>|default) |
| handover2 assignment (0|1|default) |
| handover2 tdma-measurement (full|subset|default) |
| handover2 min rxlev (<-110--50>|default) |
| handover2 min rxqual (<0-7>|default) |
| handover2 afs-bias rxlev (<0-20>|default) |
| handover2 afs-bias rxqual (<0-7>|default) |
| handover2 min-free-slots tch/f (<0-9999>|default) |
| handover2 min-free-slots tch/h (<0-9999>|default) |
| handover2 max-handovers (<1-9999>|default) |
| handover2 penalty-time max-distance (<0-99999>|default) |
| handover2 penalty-time failed-ho (<0-99999>|default) |
| handover2 penalty-time failed-assignment (<0-99999>|default) |
| handover2 retries (<0-9>|default) |
| handover2 congestion-check (disabled|<1-999>|now) |
| ... |
| |
| OsmoBSC(config-net)# handover? |
| handover Handover general config |
| |
| OsmoBSC(config-net)# handover2? |
| handover2 Handover options for handover decision algorithm 2 |
| |
| OsmoBSC(config-net)# handover ? |
| 0 Disable in-call handover |
| 1 Enable in-call handover |
| default Enable/disable handover: Use default (0), remove explicit setting on this node |
| algorithm Choose algorithm for handover decision |
| window Measurement averaging settings |
| power Neighbor cell power triggering |
| maximum Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| |
| OsmoBSC(config-net)# handover2 ? |
| window Measurement averaging settings |
| power Neighbor cell power triggering |
| maximum Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| assignment Enable or disable in-call channel re-assignment (HO algo 2 only) |
| tdma-measurement Define measurement set of TDMA frames (HO algo 2 only) |
| min Minimum Level/Quality thresholds before triggering HO (HO algo 2 only) |
| afs-bias Configure bias to prefer AFS (AMR on TCH/F) over other codecs (HO algo 2 only) |
| min-free-slots Minimum free TCH timeslots before cell is considered congested (HO algo 2 only) |
| max-handovers Maximum number of concurrent handovers allowed per cell (HO algo 2 only) |
| penalty-time Set penalty times to wait between repeated handovers (HO algo 2 only) |
| retries Immediately retry on handover/assignment failure (HO algo 2 only) |
| congestion-check Configure congestion check interval (HO algo 2 only) |
| |
| OsmoBSC(config-net)# handover algorithm ? |
| 1 Algorithm 1: trigger handover based on comparing current cell and neighbor RxLev and RxQual, only. |
| 2 Algorithm 2: trigger handover on RxLev/RxQual, and also to balance the load across several cells. Consider available codecs. Prevent repeated handover by penalty timers. |
| default Use default (1), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover window ? |
| rxlev Received-Level averaging |
| rxqual Received-Quality averaging |
| |
| OsmoBSC(config-net)# handover window rxlev ? |
| averaging How many RxLev measurements are used for averaging |
| neighbor How many Neighbor RxLev measurements are used for averaging |
| |
| OsmoBSC(config-net)# handover window rxlev averaging ? |
| <1-10> RxLev averaging: Number of values to average over |
| default Use default (10), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover window rxlev neighbor ? |
| averaging How many Neighbor RxLev measurements are used for averaging |
| |
| OsmoBSC(config-net)# handover window rxlev neighbor averaging ? |
| <1-10> Neighbor RxLev averaging: Number of values to average over |
| default Use default (10), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover window rxqual ? |
| averaging How many RxQual measurements are used for averaging |
| |
| OsmoBSC(config-net)# handover window rxqual averaging ? |
| <1-10> RxQual averaging: Number of values to average over |
| default Use default (1), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover power ? |
| budget Neighbor cell power triggering |
| |
| OsmoBSC(config-net)# handover power budget ? |
| interval How often to check for a better cell (SACCH frames) |
| hysteresis How many dBm stronger must a neighbor be to become a HO candidate |
| |
| OsmoBSC(config-net)# handover power budget interval ? |
| <1-99> Check for stronger neighbor every N number of SACCH frames |
| default Use default (6), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover power budget hysteresis ? |
| <0-999> Neighbor's strength difference in dBm |
| default Use default (3), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover maximum ? |
| distance Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| |
| OsmoBSC(config-net)# handover maximum distance ? |
| <0-9999> Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| default Use default (9999), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 window ? |
| rxlev Received-Level averaging |
| rxqual Received-Quality averaging |
| |
| OsmoBSC(config-net)# handover2 window rxlev ? |
| averaging How many RxLev measurements are used for averaging |
| neighbor How many Neighbor RxLev measurements are used for averaging |
| |
| OsmoBSC(config-net)# handover2 window rxlev averaging ? |
| <1-10> RxLev averaging: Number of values to average over |
| default Use default (10), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 window rxlev neighbor ? |
| averaging How many Neighbor RxLev measurements are used for averaging |
| |
| OsmoBSC(config-net)# handover2 window rxlev neighbor averaging ? |
| <1-10> Neighbor RxLev averaging: Number of values to average over |
| default Use default (10), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 window rxqual ? |
| averaging How many RxQual measurements are used for averaging |
| |
| OsmoBSC(config-net)# handover2 window rxqual averaging ? |
| <1-10> RxQual averaging: Number of values to average over |
| default Use default (1), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 power ? |
| budget Neighbor cell power triggering |
| |
| OsmoBSC(config-net)# handover2 power budget ? |
| interval How often to check for a better cell (SACCH frames) |
| hysteresis How many dBm stronger must a neighbor be to become a HO candidate |
| |
| OsmoBSC(config-net)# handover2 power budget interval ? |
| <1-99> Check for stronger neighbor every N number of SACCH frames |
| default Use default (6), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 power budget hysteresis ? |
| <0-999> Neighbor's strength difference in dBm |
| default Use default (3), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 maximum ? |
| distance Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| |
| OsmoBSC(config-net)# handover2 maximum distance ? |
| <0-9999> Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| default Use default (9999), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 assignment ? |
| 0 Disable in-call assignment |
| 1 Enable in-call assignment |
| default Use default (0), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 tdma-measurement ? |
| full Full set of 102/104 TDMA frames |
| subset Sub set of 4 TDMA frames (SACCH) |
| default Use default (subset), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 min ? |
| rxlev How weak may RxLev of an MS become before triggering HO |
| rxqual How bad may RxQual of an MS become before triggering HO |
| |
| OsmoBSC(config-net)# handover2 min rxlev ? |
| <-110--50> minimum RxLev (dBm) |
| default Use default (-100), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 min rxqual ? |
| <0-7> minimum RxQual (dBm) |
| default Use default (5), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 afs-bias ? |
| rxlev RxLev improvement bias for AFS over other codecs |
| rxqual RxQual improvement bias for AFS over other codecs |
| |
| OsmoBSC(config-net)# handover2 afs-bias rxlev ? |
| <0-20> Virtual RxLev improvement (dBm) |
| default Use default (0), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 afs-bias rxqual ? |
| <0-7> Virtual RxQual improvement (dBm) |
| default Use default (0), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 min-free-slots ? |
| tch/f Minimum free TCH/F timeslots before cell is considered congested |
| tch/h Minimum free TCH/H timeslots before cell is considered congested |
| |
| OsmoBSC(config-net)# handover2 min-free-slots tch/f ? |
| <0-9999> Number of TCH/F slots |
| default Use default (0), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 min-free-slots TCH/F ? |
| % There is no matched command. |
| |
| OsmoBSC(config-net)# handover2 min-free-slots tch/h ? |
| <0-9999> Number of TCH/H slots |
| default Use default (0), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 max-handovers ? |
| <1-9999> Number |
| default Use default (9999), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 penalty-time ? |
| max-distance Time to suspend handovers after leaving this cell due to exceeding max distance |
| failed-ho Time to suspend handovers after handover failure to this cell |
| failed-assignment Time to suspend handovers after assignment failure in this cell |
| |
| OsmoBSC(config-net)# handover2 penalty-time max-distance ? |
| <0-99999> Seconds |
| default Use default (300), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 penalty-time failed-ho ? |
| <0-99999> Seconds |
| default Use default (60), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 penalty-time failed-assignment ? |
| <0-99999> Seconds |
| default Use default (60), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 retries ? |
| <0-9> Number of retries |
| default Use default (0), remove explicit setting on this node |
| |
| OsmoBSC(config-net)# handover2 congestion-check ? |
| disabled Disable congestion checking, do not handover based on cell overload |
| <1-999> Congestion check interval in seconds (default 10) |
| now Manually trigger a congestion check to run right now |
| |
| |
| OsmoBSC(config-net)# ### Same on BTS level, except for the congestion-check |
| OsmoBSC(config-net)# bts 0 |
| |
| OsmoBSC(config-net-bts)# handover? |
| handover Handover general config |
| |
| OsmoBSC(config-net-bts)# handover2? |
| handover2 Handover options for handover decision algorithm 2 |
| |
| OsmoBSC(config-net-bts)# handover ? |
| 0 Disable in-call handover |
| 1 Enable in-call handover |
| default Enable/disable handover: Use default (0), remove explicit setting on this node |
| algorithm Choose algorithm for handover decision |
| window Measurement averaging settings |
| power Neighbor cell power triggering |
| maximum Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| |
| OsmoBSC(config-net-bts)# handover2 ? |
| window Measurement averaging settings |
| power Neighbor cell power triggering |
| maximum Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| assignment Enable or disable in-call channel re-assignment (HO algo 2 only) |
| tdma-measurement Define measurement set of TDMA frames (HO algo 2 only) |
| min Minimum Level/Quality thresholds before triggering HO (HO algo 2 only) |
| afs-bias Configure bias to prefer AFS (AMR on TCH/F) over other codecs (HO algo 2 only) |
| min-free-slots Minimum free TCH timeslots before cell is considered congested (HO algo 2 only) |
| max-handovers Maximum number of concurrent handovers allowed per cell (HO algo 2 only) |
| penalty-time Set penalty times to wait between repeated handovers (HO algo 2 only) |
| retries Immediately retry on handover/assignment failure (HO algo 2 only) |
| |
| OsmoBSC(config-net-bts)# handover algorithm ? |
| 1 Algorithm 1: trigger handover based on comparing current cell and neighbor RxLev and RxQual, only. |
| 2 Algorithm 2: trigger handover on RxLev/RxQual, and also to balance the load across several cells. Consider available codecs. Prevent repeated handover by penalty timers. |
| default Use default (1), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover window ? |
| rxlev Received-Level averaging |
| rxqual Received-Quality averaging |
| |
| OsmoBSC(config-net-bts)# handover window rxlev ? |
| averaging How many RxLev measurements are used for averaging |
| neighbor How many Neighbor RxLev measurements are used for averaging |
| |
| OsmoBSC(config-net-bts)# handover window rxlev averaging ? |
| <1-10> RxLev averaging: Number of values to average over |
| default Use default (10), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover window rxlev neighbor ? |
| averaging How many Neighbor RxLev measurements are used for averaging |
| |
| OsmoBSC(config-net-bts)# handover window rxlev neighbor averaging ? |
| <1-10> Neighbor RxLev averaging: Number of values to average over |
| default Use default (10), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover window rxqual ? |
| averaging How many RxQual measurements are used for averaging |
| |
| OsmoBSC(config-net-bts)# handover window rxqual averaging ? |
| <1-10> RxQual averaging: Number of values to average over |
| default Use default (1), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover power ? |
| budget Neighbor cell power triggering |
| |
| OsmoBSC(config-net-bts)# handover power budget ? |
| interval How often to check for a better cell (SACCH frames) |
| hysteresis How many dBm stronger must a neighbor be to become a HO candidate |
| |
| OsmoBSC(config-net-bts)# handover power budget interval ? |
| <1-99> Check for stronger neighbor every N number of SACCH frames |
| default Use default (6), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover power budget hysteresis ? |
| <0-999> Neighbor's strength difference in dBm |
| default Use default (3), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover maximum ? |
| distance Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| |
| OsmoBSC(config-net-bts)# handover maximum distance ? |
| <0-9999> Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| default Use default (9999), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 window ? |
| rxlev Received-Level averaging |
| rxqual Received-Quality averaging |
| |
| OsmoBSC(config-net-bts)# handover2 window rxlev ? |
| averaging How many RxLev measurements are used for averaging |
| neighbor How many Neighbor RxLev measurements are used for averaging |
| |
| OsmoBSC(config-net-bts)# handover2 window rxlev averaging ? |
| <1-10> RxLev averaging: Number of values to average over |
| default Use default (10), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 window rxlev neighbor ? |
| averaging How many Neighbor RxLev measurements are used for averaging |
| |
| OsmoBSC(config-net-bts)# handover2 window rxlev neighbor averaging ? |
| <1-10> Neighbor RxLev averaging: Number of values to average over |
| default Use default (10), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 window rxqual ? |
| averaging How many RxQual measurements are used for averaging |
| |
| OsmoBSC(config-net-bts)# handover2 window rxqual averaging ? |
| <1-10> RxQual averaging: Number of values to average over |
| default Use default (1), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 power ? |
| budget Neighbor cell power triggering |
| |
| OsmoBSC(config-net-bts)# handover2 power budget ? |
| interval How often to check for a better cell (SACCH frames) |
| hysteresis How many dBm stronger must a neighbor be to become a HO candidate |
| |
| OsmoBSC(config-net-bts)# handover2 power budget interval ? |
| <1-99> Check for stronger neighbor every N number of SACCH frames |
| default Use default (6), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 power budget hysteresis ? |
| <0-999> Neighbor's strength difference in dBm |
| default Use default (3), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 maximum ? |
| distance Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| |
| OsmoBSC(config-net-bts)# handover2 maximum distance ? |
| <0-9999> Maximum Timing-Advance value (i.e. MS distance) before triggering HO |
| default Use default (9999), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 assignment ? |
| 0 Disable in-call assignment |
| 1 Enable in-call assignment |
| default Use default (0), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 tdma-measurement ? |
| full Full set of 102/104 TDMA frames |
| subset Sub set of 4 TDMA frames (SACCH) |
| default Use default (subset), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 min ? |
| rxlev How weak may RxLev of an MS become before triggering HO |
| rxqual How bad may RxQual of an MS become before triggering HO |
| |
| OsmoBSC(config-net-bts)# handover2 min rxlev ? |
| <-110--50> minimum RxLev (dBm) |
| default Use default (-100), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 min rxqual ? |
| <0-7> minimum RxQual (dBm) |
| default Use default (5), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 afs-bias ? |
| rxlev RxLev improvement bias for AFS over other codecs |
| rxqual RxQual improvement bias for AFS over other codecs |
| |
| OsmoBSC(config-net-bts)# handover2 afs-bias rxlev ? |
| <0-20> Virtual RxLev improvement (dBm) |
| default Use default (0), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 afs-bias rxqual ? |
| <0-7> Virtual RxQual improvement (dBm) |
| default Use default (0), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 min-free-slots ? |
| tch/f Minimum free TCH/F timeslots before cell is considered congested |
| tch/h Minimum free TCH/H timeslots before cell is considered congested |
| |
| OsmoBSC(config-net-bts)# handover2 min-free-slots tch/f ? |
| <0-9999> Number of TCH/F slots |
| default Use default (0), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 min-free-slots TCH/F ? |
| % There is no matched command. |
| |
| OsmoBSC(config-net-bts)# handover2 min-free-slots tch/h ? |
| <0-9999> Number of TCH/H slots |
| default Use default (0), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 max-handovers ? |
| <1-9999> Number |
| default Use default (9999), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 penalty-time ? |
| max-distance Time to suspend handovers after leaving this cell due to exceeding max distance |
| failed-ho Time to suspend handovers after handover failure to this cell |
| failed-assignment Time to suspend handovers after assignment failure in this cell |
| |
| OsmoBSC(config-net-bts)# handover2 penalty-time max-distance ? |
| <0-99999> Seconds |
| default Use default (300), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 penalty-time failed-ho ? |
| <0-99999> Seconds |
| default Use default (60), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 penalty-time failed-assignment ? |
| <0-99999> Seconds |
| default Use default (60), remove explicit setting on this node |
| |
| OsmoBSC(config-net-bts)# handover2 retries ? |
| <0-9> Number of retries |
| default Use default (0), remove explicit setting on this node |