utils: Remove format_xplmn leading zeros in MNC
Change-Id: I803edafbd892c2b32b884d0b39fed61967a3d68b
diff --git a/pysim-testdata/sysmoUSIM-SJS1.ok b/pysim-testdata/sysmoUSIM-SJS1.ok
index b4277f4..b793cc0 100644
--- a/pysim-testdata/sysmoUSIM-SJS1.ok
+++ b/pysim-testdata/sysmoUSIM-SJS1.ok
@@ -105,10 +105,10 @@
Service 59 - MMS User Connectivity Parameters
FPLMN:
- 62f201 # MCC: 262 MNC: 010
- 62f202 # MCC: 262 MNC: 020
- 62f203 # MCC: 262 MNC: 030
- 62f207 # MCC: 262 MNC: 070
+ 62f201 # MCC: 262 MNC: 10
+ 62f202 # MCC: 262 MNC: 20
+ 62f203 # MCC: 262 MNC: 30
+ 62f207 # MCC: 262 MNC: 70
USIM Service Table: 9e6b1dfc67f6580000
Service 2 - Fixed Dialling Numbers (FDN)