BSC_Tests: add support for per-TRX RSL connections

So far it was possible to communicate with multiple BTS instances,
however we were limited to only one IPA/RSL connection per BTS.
Communicating with additional TRX instances requires establishing
additional per-TRX IPA/RSL connections.  This patch extends the
testsuite infrastructure, so that it becomes possible to have
up to 4 individual TRX instances for each BTS.

* Introduce record 'BtsParams', store per-BTS params in an array.
* IPA_RSL_PT: test_CT.IPA_RSL[NUM_BTS] -> test_CT.IPA_RSL[NUM_BTS][NUM_TRX].
* BTS_State: test_CT.bts[NUM_BTS] -> test_CT.bts[NUM_BTS][NUM_TRX].
* f_init_bts_and_check_sysinfo() accepts number of TRX instances.
* f_init_bts() accepts number of TRX instances to configure.
* f_ipa_rsl_start() accepts a BtsTrxIdx param.

* Introduce record BtsTrxIdx allowing to specify BTS/TRX index values.
* f_ipa_tx(), f_exp_ipa_rx() accept a BtsTrxIdx param (default {0, 0}).
* f_est_dchan[_dyn]() accept a BtsTrxIdx param (default {0, 0}).
** and store the given BtsTrxIdx in returned DchanTuple.
* f_chreq_act_ack() accepts a BtsTrxIdx param (default {0, 0}).
* f_expect_chan_rel() accepts a BtsTrxIdx param (default {0, 0}).
* f_exp_ipa_rx_nonfatal() accepts BtsTrxIdx (default {0, 0}).
* f_exp_chan_rel_and_clear() uses BtsTrxIdx indicated in the given DchanTuple.

* Fix CTRL/statsd expectations in TC_stat_num_bts_connected_[123].
* Fix CTRL expectations in TC_ctrl_trx_rf_locked.

The major limitation is that MSC_ConnHdlr components still have no
access to additional TRX instances - this can be implemented later.

Change-Id: Ic0fd97234464ef624010a5f01189aa61f3393b84
Related: SYS#5460
4 files changed