bsc: Log wrong and expected values if MS Power level verification fails
Change-Id: Idacfdb8d9061d78ce6fa521d4008974c2d3d74df
diff --git a/bsc/MSC_ConnectionHandler.ttcn b/bsc/MSC_ConnectionHandler.ttcn
index 8091d8d..09190e3 100644
--- a/bsc/MSC_ConnectionHandler.ttcn
+++ b/bsc/MSC_ConnectionHandler.ttcn
@@ -760,7 +760,7 @@
}
}
/* FIXME: validate RSL_IE_ACT_TYPE, RSL_IE_CHAN_MODE, RSL_IE_CHAN_IDENT, RSL_IE_BS_POWER,
- * RSL_IE_MS_POWER, RSL_IE_TIMING_ADVANCE */
+ * RSL_IE_TIMING_ADVANCE */
if (not f_rsl_find_ie(chan_act, RSL_IE_MS_POWER_PARAM, ms_power_param)) {
Misc_Helpers.f_shutdown(__BFILE__, __LINE__, fail, "IE MS Power Parameters not found in CHAN ACT");
@@ -770,7 +770,7 @@
Misc_Helpers.f_shutdown(__BFILE__, __LINE__, fail, "IE MS Power not found in CHAN ACT");
} else {
if (not match(ms_power.ms_power, tr_RSL_IE_MS_Power(g_pars.exp_ms_power_level, false))) {
- Misc_Helpers.f_shutdown(__BFILE__, __LINE__, fail, "Wrong MS Power IE in CHAN ACT");
+ Misc_Helpers.f_shutdown(__BFILE__, __LINE__, fail, log2str("Wrong MS Power IE in CHAN ACT, ", ms_power.ms_power.power_level, " vs exp ", g_pars.exp_ms_power_level));
}
}