OM2000: CON MO: Allow larger range for CCP and CI values

it seesm more recent RBS2000 models have much larger CCP and CI value ranges
than those of older models.

Change-Id: Ib116c1fac901b293929fce34223d1fd0af15d2bc
diff --git a/openbsc/src/libbsc/abis_om2000_vty.c b/openbsc/src/libbsc/abis_om2000_vty.c
index 2a89d49..27b1947 100644
--- a/openbsc/src/libbsc/abis_om2000_vty.c
+++ b/openbsc/src/libbsc/abis_om2000_vty.c
@@ -349,7 +349,7 @@
 			"Contiguity Index\n"				\
 
 DEFUN(cfg_om2k_con_path_dec, cfg_om2k_con_path_dec_cmd,
-	"con-path (add|del) <0-1023> <0-7> deconcentrated <0-63>",
+	"con-path (add|del) <0-2047> <0-255> deconcentrated <0-63>",
 	CON_PATH_HELP "De-concentrated in/outlet\n" "TEI Value\n")
 {
 	struct con_group *cg = vty->index;
@@ -371,7 +371,7 @@
 }
 
 DEFUN(cfg_om2k_con_path_conc, cfg_om2k_con_path_conc_cmd,
-	"con-path (add|del) <0-1023> <0-7> concentrated <1-16>",
+	"con-path (add|del) <0-2047> <0-255> concentrated <1-16>",
 	CON_PATH_HELP "Concentrated in/outlet\n" "Tag Number\n")
 {
 	struct con_group *cg = vty->index;