poll: Use the data_ind FN as time source for current frame

The FN of the data_ind taken from the DSP are monotonic, so latency
does not affect the detection of poll timeouts if these FN are used.
If the FN is larger than a poll_fn value, it can safely be assumed
that the poll response will not arrive later on.

Currently a max_delay of 60 frames is used, which has the drawback
that additional ~250ms will pass until a lost ACK is detected.

Using the data_ind's FN alone breaks the poll timeout detection if
there are no other MS sending data blocks.

This commit adds BTS::set_current_block_frame_number that is called
with the FN taken from data_ind messages. The max_delay is set to 0
which removes the additional delay, when this FN is used to detect
poll timeouts. So the average additional delay decreases with the
number of data_ind per time. The current_frame is updated unless it
seems to have been updated already (assumed if 0 < cur_fn - block_fn
< 500). Thus the time_ind has still priority to update the
current_frame value.

Sponsored-by: On-Waves ehf
3 files changed