commit | 0b874b64ef36fb2abc87ed2c0ea52b6fa582fa4b | [log] [tgz] |
---|---|---|
author | Andreas Eversberg <jolly@eversberg.eu> | Sat Mar 16 15:56:01 2013 +0100 |
committer | Andreas Eversberg <jolly@eversberg.eu> | Sat Mar 16 15:56:01 2013 +0100 |
tree | 23955aeae0c8cc2fe89fa7be82a86fa30352fedf | |
parent | 30a73d8544edc9c160df3f14095934ee59bddbb1 [diff] |
Use default 'alpha' value of 0 Since we don't know the RX and TX parameters of the BTS that might be used with PCU, the MS should not adapt the TX power from the RX level. So the MS should always transmits with same power. Finding an 'alpha' and 'gamma' value that will result in a constant RX level at the BTS is a task of deployment.