RANAP-PDU-Contents: fix syntax error regarding InitialUE-Message
With that syntax error, the RAC was not treated as a possible IE
in the InitialUE-Message, causing decoder failure.
diff --git a/asn1/ranap/RANAP-PDU-Contents.asn b/asn1/ranap/RANAP-PDU-Contents.asn
index bc532bc..75aeaeb 100644
--- a/asn1/ranap/RANAP-PDU-Contents.asn
+++ b/asn1/ranap/RANAP-PDU-Contents.asn
@@ -1924,7 +1924,7 @@
InitialUE-MessageIEs RANAP-PROTOCOL-IES ::= {
{ ID id-CN-DomainIndicator CRITICALITY ignore TYPE CN-DomainIndicator PRESENCE mandatory } |
{ ID id-LAI CRITICALITY ignore TYPE LAI PRESENCE mandatory } |
- { ID id-RAC CRITICALITY ignore TYPE RAC PRESENCE conditional
+ { ID id-RAC CRITICALITY ignore TYPE RAC PRESENCE conditional } |
-- This IE shall be present if the CN Domain Indicator IE is set to "PS domain" -- } |
{ ID id-SAI CRITICALITY ignore TYPE SAI PRESENCE mandatory } |
{ ID id-NAS-PDU CRITICALITY ignore TYPE NAS-PDU PRESENCE mandatory } |