amarisoft_enb: fix RI config
this cause all MIMO modes to fail because RI reporting was disabled
Change-Id: Ic25233cf7feb4ded8b3d0f440191cc958d8bc0ec
diff --git a/src/osmo_gsm_tester/templates/amarisoft_enb.cfg.tmpl b/src/osmo_gsm_tester/templates/amarisoft_enb.cfg.tmpl
index 29b5fb8..8bb55d3 100644
--- a/src/osmo_gsm_tester/templates/amarisoft_enb.cfg.tmpl
+++ b/src/osmo_gsm_tester/templates/amarisoft_enb.cfg.tmpl
@@ -152,11 +152,13 @@
sr_period: 20,
/* CQI report config */
- cqi_period: 40, /* period (ms). Must be >= 32 for HD-FDD */
+ cqi_period: 160, /* period (ms). Must be >= 32 for HD-FDD */
/* RI reporting is done with a period of m_ri * cqi_period.
m_ri = 0 (default) disables RI reporting. */
-// m_ri: 8,
+ % if int(enb.get('transmission_mode')) > 1:
+ m_ri: 8,
+ % endif
pucch_dedicated: {
/* ack/nack feedback mode when carrier aggregation is