commit | 0c976882b4222a7ad188569fca4e8d077c239ef7 | [log] [tgz] |
---|---|---|
author | Holger Hans Peter Freyther <holger@moiji-mobile.com> | Fri Jul 04 20:55:20 2014 +0200 |
committer | Holger Hans Peter Freyther <holger@moiji-mobile.com> | Tue Jul 22 14:31:35 2014 +0200 |
tree | d4167b35cdc4c968d1f2234842f7b70ea1a980ff | |
parent | 1f964682ae47bfec9e6c4622a1c6ccd002045b4c [diff] |
mgcp: Fix/test reading/writing the sequence number The sequence number was read from the wrong place and then the wrong byte order conversion routine was used so we ended up wirting 0x00, 0x00 into the patched sequence number. Add a testcase for that.