vty: fix OML link state printing
Always print newline regardless of BTS uptime availability.
Change-Id: Ib80049fe66de17bc7acfbb774a30075f40a44dee
diff --git a/src/libbsc/bsc_vty.c b/src/libbsc/bsc_vty.c
index 8281606..e60bdaf 100644
--- a/src/libbsc/bsc_vty.c
+++ b/src/libbsc/bsc_vty.c
@@ -298,9 +298,9 @@
vty_out(vty, " OML Link state: %s", get_model_oml_status(bts));
sec = bts_uptime(bts);
if (sec)
- vty_out(vty, " %llu days %llu hours %llu min. %llu sec.%s",
- OSMO_SEC2DAY(sec), OSMO_SEC2HRS(sec), OSMO_SEC2MIN(sec), sec % 60,
- VTY_NEWLINE);
+ vty_out(vty, " %llu days %llu hours %llu min. %llu sec.",
+ OSMO_SEC2DAY(sec), OSMO_SEC2HRS(sec), OSMO_SEC2MIN(sec), sec % 60);
+ vty_out(vty, "%s", VTY_NEWLINE);
} else {
vty_out(vty, " E1 Signalling Link:%s", VTY_NEWLINE);
e1isl_dump_vty(vty, bts->oml_link);