add Ericsson OM2000 message sequence charts (one for each MO)
diff --git a/doc/manuals/om2000/om2k-mo-tf.msc b/doc/manuals/om2000/om2k-mo-tf.msc
new file mode 100644
index 0000000..ae1cdfd
--- /dev/null
+++ b/doc/manuals/om2000/om2k-mo-tf.msc
@@ -0,0 +1,29 @@
+msc {
+	bts [label="BTS"], bsc [label="BSC"];
+	# this is for the Timing Funcition Object
+	---		[label="Initial state after initializing CF"];
+
+	bts <= bsc	[label="Connect Command"];
+	bts => bsc	[label="Connect Complete"];
+
+	bts <= bsc	[label="Reset Command"];
+	bts => bsc	[label="Reset Complete"];
+
+	bts <= bsc	[label="Start Request"];
+	bts => bsc	[label="Reset Request Accept"];
+	bts => bsc	[label="Start Result (Disabled)"];
+	bts <= bsc	[label="Start Result ACK"];
+
+	bts <= bsc	[label="TF Configuration Request"];
+	bts => bsc	[label="TF Configuration Request Accept"];
+	bts => bsc	[label="TF Configuration Result (According to Req)"];
+	bts <= bsc	[label="TF Configuration Result ACK"];
+
+	bts <= bsc	[label="Enable Request"];
+	bts => bsc	[label="Enable Request Accept"];
+	bts => bsc	[label="Enable Result (Enabled)"];
+	bts <= bsc	[label="Enable Result ACK"];
+
+	bts <= bsc	[label="Operational Info (Operational)"];
+	bts => bsc	[label="Operational Info Accept"];
+}