add Ericsson OM2000 message sequence charts (one for each MO)
diff --git a/doc/manuals/om2000/om2k-mo-tf.msc b/doc/manuals/om2000/om2k-mo-tf.msc
new file mode 100644
index 0000000..ae1cdfd
--- /dev/null
+++ b/doc/manuals/om2000/om2k-mo-tf.msc
@@ -0,0 +1,29 @@
+msc {
+ bts [label="BTS"], bsc [label="BSC"];
+ # this is for the Timing Funcition Object
+ --- [label="Initial state after initializing CF"];
+
+ bts <= bsc [label="Connect Command"];
+ bts => bsc [label="Connect Complete"];
+
+ bts <= bsc [label="Reset Command"];
+ bts => bsc [label="Reset Complete"];
+
+ bts <= bsc [label="Start Request"];
+ bts => bsc [label="Reset Request Accept"];
+ bts => bsc [label="Start Result (Disabled)"];
+ bts <= bsc [label="Start Result ACK"];
+
+ bts <= bsc [label="TF Configuration Request"];
+ bts => bsc [label="TF Configuration Request Accept"];
+ bts => bsc [label="TF Configuration Result (According to Req)"];
+ bts <= bsc [label="TF Configuration Result ACK"];
+
+ bts <= bsc [label="Enable Request"];
+ bts => bsc [label="Enable Request Accept"];
+ bts => bsc [label="Enable Result (Enabled)"];
+ bts <= bsc [label="Enable Result ACK"];
+
+ bts <= bsc [label="Operational Info (Operational)"];
+ bts => bsc [label="Operational Info Accept"];
+}